IEC 61340-3-1 Ed. 1.0 b:2002

Original price was: $42.00.Current price is: $21.00.

Electrostatics – Part 3-1: Methods for simulation of electrostatic effects – Human body model (HBM) – Component testing

International Electrotechnical Commission , 03/20/2002

Pages: 19

Category:
Describes the discharge current waveforms used to define the HBM and the basic equipment requirements used to develop these waveforms. Test parameters are defined for testing and classifying the electrostatic discharge (ESD) sensitivity of non-powered devices to the HBM. The purpose of this standard is to establish a test model that will replicate HBM failures and will define the HBM transient current discharge waveform and all necessary test parameters to ensure reliable, reproducible test results. Reproducible data will allow accurate comparisons of HBM ESD sensitivity levels.