- from the level difference before and after the installation of noise barriers (the “direct method”);
- when the direct method is not applicable, because a barrier has already been installed, using an “indirect method” to estimate the sound pressure levels before installation of the barrier by measurement at another site which has been judged to be equivalent.
For equivalent sites, a close match is required in source characteristics, microphone locations, terrain profiles ground surface characteristics, surrounding artificial structures and meteorological conditions. This Technical Specification prescribes principles for ensuring that sufficiently equivalent conditions are maintained between “before” and “after” cases to permit certain, reliable and repeatable determination of barrier insertion loss. This Technical Specification does not cover the determination of the intrinsic acoustic characteristics of the barrier, for example the sound insulation index and the sound absorption coefficient. The equivalent continuous A-weighted sound pressure level and one-third-octave band sound pressure level are used as noise descriptors. This Technical Specification can be used for routine determination of barrier performance or for engineering or diagnostic evaluation. It can be used in situations where the barrier is to be installed or has already been installed.Cross References:EN 60942IEC 60942EN 61260IEC 61260EN 61672-1 IEC 61672-1ISO/IEC Guide 98-3GUM:1995EN 16272-3-1EN 16272-3-2ISO 9613-1