PCCP is used principally in the transmission and distribution of water in municipal, industrial, and irrigation systems. It is also used in plant piping systems, seawater cooling systems, sewer force mains, and gravity sewers. Other applications include inverted siphons, liners for pressure tunnels, and culverts with high earth covers.
The major revisions made to the standard in this edition include the following:
1. The unit weights for concrete and mortar have been made consistent throughout the standard.
2. An alternate criterion has been added for surcharge load computed in accordance with recognized and documented analytical procedures based on soil?pipe interaction.
3. The design yield strength of the steel cylinder in tension has been changed.
4. Numerous editorial improvements and reference updates have been made throughout.